b'Osbournes Model WPL80 (Flanged). Line of jamb flashing.40 x 40 x 3 fixing angle pop rivited to back offrame @ 300mm c/c. Fix to plate Provide sill flashing with 5 slope to exterior &with wood screws @ 300mm c/c. hem to back edge and 20mm min upstand at bothends Do not seal to joinery.Sloped sill trimmer to suit. 30mm min cover to joineryBuilding wrap to return into louvre opening.Provide flashing tape over wrap as per WANZ 5 5window installation system. 50mm min cover to claddingCompressible foam.Timber wall framing with wall insulation as Selected profiled exterior metal sheetspecified by Architect. cladding on 20mm H3.1 vertical timber battensto Architects specification.Model WPL 80 (Flanged Frame)Typical Vertical Corrugate/Louvre Sill Detail 03 Osbournes LtdScale 1:5General Notes:Flashing materials must be selected based on environmental exposure, refer to NZS 3604:1999.Building wrap must comply with acceptable solution E2/AS1 & NZS 3604:1999.Flashing tape must have proven compatibility with the selected building wrap & other materials with which it comes into contact.Refer to the manufacturer or supplier for technical information of all materials.This is an untested alternative solution to NZBC E2/AS1.This information is intended to be informative and used as a guideline only. Due to the many variables affecting different projectsOsbournes Ltd can not replace the judgment or advice of an Architect, Engineer or any other relevanttechnical expert and such experts must be consulted to determine the suitability or otherwise of the details or the necessity forfurther design/detailing.Page 18'