b'Osbournes Model WPL50 (Flanged). Line of jamb flashing.40 x 25 x 3 fixing angle pop rivited to back of Provide sill flashing with 10slope to exterior &frame @ 300mm c/c. Fix to plate hem to back edge with 20mm min upstand atwith wood screws @ 300mm c/c. both ends . Provide 25mm cover min to flashing.Flashing to cover at least one corrugation.Sloped sill trimmer to suit. 10mm min cover to flashing5Building wrap to return into louvre opening. 5 Close end of flashing and scribe to suit claddingProvide flashing tape over wrap as per WANZ profile. Pop rivit to cladding.window installation system. Selected profiled exterior metal sheetTimber wall framing with wall insulation as cladding on 20mm H3.1 vertical timber battensspecified by Architect. to Architects specification.Model WPL 50 (Flanged Frame)Typical Horizontal Corrugate/Louvre Sill Detail 03Osbournes LtdScale 1:5General Notes:Flashing materials must be selected based on environmental exposure, refer to NZS 3604:1999.Building wrap must comply with acceptable solution NZBC E2/AS1 & NZS 3604:1999.Flashing tape must have proven compatibility with the selected building wrap & other materials with which it comes into contact.Refer to the manufacturer or supplier for technical information of all materials.This is an untested alternative solution to NZBC E2/AS1.This information is intended to be informative and used as a guideline only. Due to the many variables affecting different projectsOsbournes Ltd can not replace the judgment or advice of an Architect, Engineer or any other relevanttechnical expert and such experts must be consulted to determine the suitability or otherwise of the details or the necessity forfurther design/detailing.Page 9'