b'Osbournes Model WPL50 (Flanged). Line of jamb flashing.40 x 25 x 3 fixing angle pop rivited to back of Provide sill flashing with 5 slope to exterior &frame @ 300mm c/c. Fix to plate hem to back edge and 20mm min upstand at bothwith wood screws @ 300mm c/c. ends Do not seal to joinery.Sloped sill trimmer to suit. 15mm min cover to joineryBuilding wrap to return into louvre opening. 5 5Provide flashing tape over wrap as per WANZ 50mm min cover to claddingwindow installation system.Compressible foam. Selected profiled exterior metal sheetTimber wall framing with wall insulation as cladding on 20mm H3.1 vertical timber battensspecified by Architect. to Architects specification.Model WPL 50 (Flanged Frame)Typical Vertical Corrugate/Louvre Sill Detail 03 Osbournes LtdScale 1:5General Notes:Flashing materials must be selected based on environmental exposure, refer to NZS 3604:1999.Building wrap must comply with acceptable solution E2/AS1 & NZS 3604:1999.Flashing tape must have proven compatibility with the selected building wrap & other materials with which it comes into contact.Refer to the manufacturer or supplier for technical information of all materials.This is an untested alternative solution to NZBC E2/AS1.This information is intended to be informative and used as a guideline only. Due to the many variables affecting different projectsOsbournes Ltd can not replace the judgment or advice of an Architect, Engineer or any other relevanttechnical expert and such experts must be consulted to determine the suitability or otherwise of the details or the necessity forfurther design/detailing.Page 7'